other
Products
Home

Products

DC/DC converter

GST-H150S18-M

GST-H150S18-M

  • Brand:

    POWERLD
  • Item NO.:

    GST-H150S18-M
  • Wattage (W):

    150
  • Input:

    176-264Vac
  • Output:

    18
  • PFC:

    N
  • Conformal Coating:

    N
  • Approval:

    N
  • Dimension:

    450*300*250mm
  • Product Detail

SPECIFICATION                                                      


MODEL

GST-H150S18-M

OUTPUT

DC Output

18V

Rated Current

8.33A

Current Range     Note 1

0~8.33A

Ripple and Noise   Note 2

0Ta50

180mVpp

-25Ta0

400mVpp

Voltage ADJ.  Range

17~20V

Voltage Accuracy

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Line Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Set-up Time

≤4S(220Vac input, Full load)

Hold up Time

≥16mS(220Vac input, Full load)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5.0%

INPUT

Voltage Range  

176-264Vac

Frequency Range

47Hz--63Hz

Efficiency ( Typical)@25℃

≥84%@Typ.

AC Current (max.)

2.5A (220Vac)

Inrush Current (Typical)

50A@220Vac Cold start

Leakage Current

Input—output:<0.25mA     Input—PG:<3.5mA

PROTECTION

Over Load

8.75~12.5A, hiccup mode, auto recovery

Over power

157.5~225W, hiccup mode, auto recovery

Short Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-25~50;  20%~90%RH  No condensing;( refer to the derating curve)

Storage Temp. & Hum.

-40℃~85℃;  10%~95%RH  No condensing

SAFETY &EMC  

(Note3)

Safety Standards

GB4943/EN60950

Withstand Voltage

Primary-Secondary: 3.0KVac/10mA.Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA.

Isolation Resistance

10M ohms

EMS Immunity

Compliance to EN61000-4-2,4,5,8,11;

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25℃, Full load)

Dimension  (L*W*H)

199×99×38mm

Packing

20PCS/CTN, 15.2kgs, 0.053CBM

Cooling method

Cooling by free air convection

NOTE

1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.

Our industrial power supply products enjoy great popularity among customers for our good quality and competitive price.We also welcome OEM and ODM orders.

Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #
  • If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Related Products
DG-30-SX power supply
DG-30-SX

Ø  Universal AC input range(90~264Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OVP/OLP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  Can be installed on TS-35/7.5 or 35/15 Ø  100% full load burn-in test Ø  PCB with conformal coating Ø  Suitable for critical applications Ø  Cooling by free air convection Ø  3 years warranty SPECIFICATION MODEL DG-30-S12 DG-30-S24 OUTPUT DC Output 12V 24V Rated Current 2.5A 1.25A CurrentRange    Note 1 0~2.5A 0~1.25A Ripple and Noise  Note 2 10~50℃ ≤50mV ≤70mV -25~10℃ ≤100mV ≤140mV Voltage ADJ. Range 12~14V 24~28V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1% Set-up Time <1.5S @230Vac Full load Hold up Time ≥20mS @230Vac Full load Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   90Vac~264Vac, 127VDC-370VDC(input V+ connect L, input V- connect N) FrequencyRange 47Hz~63Hz Efficiency ( Typical) 82% @230Vac input, full load 85% @230Vac input, full load AC Current (max.) <0.8A Inrush Current (Typical) 50A/230Vac  Cold start Leakage Current Input—output:≤0.25mA  Input—PE: ≤3.5mA  (264Vac input, 63Hz) PROTECTION Over Load 3~4.0A, hiccup mode, auto recovery 1.5~2.5A, hiccup mode, auto recovery Over voltage 15.0~16.8V, Constant voltage, auto recovery 28.8~31.2V, Constant voltage, auto recovery Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards UL60950, EN60950 Withstand Voltage Primary-Secondary: 3KVac/10mA; Primary-PE: 1.5KVac/10mA; Secondary-PE: 0.5KVac/10mA Isolation Resistance >10Mohms EMC Emission Compliance to EN55022, EN55024 Class B Harmonic Current Compliance to EN61000-3-2,CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) 590,000Hrs (25℃, Full load) Dimension (L*W*H) 103.7*32*97.5mm Packing 36pcs/CTN, 8Kgs/CTN, 0.04cbm Cooling method Cooling by free air convection NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttps://www.powerld.com. DIN rail power supply is a kind of switching power supply, which can convert unstable input voltage into stable output voltage. We can meet all industry standards of DIN rail power supply. Learn more, follow us, and leave us a message.

LPD-350-X Power Supply
LPD-350-X

Ø  AC input selectable by switch (115Vac/230Vac) Ø  High efficiency, long life and high reliability Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃) Ø  Altitude up to 5000m Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø  3 years warranty SPECIFICATION MODEL LPD-350-12 LPD-350-24 OUTPUT DC Output 12V 24V Rated Current 29.17A 14.58A Current Range     0~29.17A 0~14.58A Ripple and Noise  Note 2 0~70℃ ≤150mV ≤150mV -25℃ ≤300mV ≤300mV Voltage ADJ. Range 10.2~13.8V 21.6~28.8V Voltage Accuracy ±1.5% ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% ±0.5% Set-up Time ≤2.3S Full load Hold up Time ≥12mS/115Vac input, Full load; ≥16mS/230Vac input, Full load Temperature Coefficient ±0.03%/℃ Overshoot <5.0% INPUT VoltageRange   90Vac~132Vac/180Vac~264Vac FrequencyRange 47Hz~63Hz Efficiency @230Vac input ≥85% ≥87% AC Current (max.) <6.8A/115Vac ; <3.4A/230Vac 2.5A Inrush Current ﹤60A@ 115Vac/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<2.0mA (Input 240Vac) PROTECTION Over Load 30.63~43.75A 15.31~21.88A Protection type: Hiccup mode, auto recovery Over Power 367.5~525W 367.5~525W Protection type: Hiccup mode, auto recovery Over voltage 13.8~16.2V 28.8~33.6V Protection type: Constant voltage, auto recovery Shorted Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards GB4943 / EN60950 Withstand Voltage Primary-Secondary:3.0KVac/10mA .Primary-PG:2.0KVac/10mA. Secondary-PG:0.5KVDC/10mA. Isolation Resistance 10M ohms EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 190*99*30mm Packing TBD Cooling method Cooling by forced air (Built-in DC fan) NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com

PS-100-X power supply
PS-100-X

Ø  High AC input 176~264Vac Ø  High power density,High effiency and reliability Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temperature (-20℃~70℃) Ø  All using105℃long life electrolytic capacitors. Ø  100% full load burn-in test Ø 3’’*5’’ compact size Ø  2 years warranty MODEL PS-100-12 PSGZM-H25S8.5 GZM-H25S12II PS-100-24 OUTPUT DC Output 12V 8.5V 12V 24V Rated Current 8.33A 3A 2 A 4.16A CurrentRange   Note 1 0~8.33A 0~3A 0~2A 0~4.16A Ripple and Noise Note 2 0~70C 100mV 120mV -20C~0 120mV 85mV 120mV 120mV Voltage ADJ. Range ±10% of rated output voltage Voltage Accuracy ±1.0% ±3.0% ±5.0% ±2.0% Line Regulation ±0.5% ±0.5% ±1.0% ±0.5% Load Regulation ±1.0% ±2.0% ±1.0% ±1.0% Set-up Time <2.0S (220Vac input, Full load) Hold up Time >10mS(220Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshootand Undershoot <5.0% INPUT VoltageRange   176Vac~264Vac FrequencyRange 47Hz--63Hz Efficiency ( Typical) 83% 85% AC Current (max.) 1.5A 0.5A 2.5A 0.3A 1.5A Inrush Current (Typical) <50A@220Vac    Cold start Leakage Current Input-Output: <0.25mA; Output-PG: <3.5mA PROTECTION Over Current 105%~150% of rated output current, hiccup mode, auto recovery Over Voltage 110%~140% of rated output voltage, hiccup mode, auto recovery Short Circuit Long term mode, Auto recovery ENVIRONMENT OperatingambTemp& Hum -20℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 10%~95%RH No condensing SAFETY &EMC   Note 3 Safety Standards GB4943-2001; EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA .Secondary-PG:0.5KVDC;≤10mA . Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55022(CISPR22)ClassB EMSImmunity Compliance to EN61000-4-2,3,4,5,6,8;ENV50204A, heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension (L*W*H) 127×76.2×32.5mm Packing 24PCS/CTN, 8.5KGS, 0.02CBM Cooling method Cooling by free air convection NOTE 1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. Focus on the development of Industrial power supply for many years,make efforts to meet customers' requirements and search for long-term cooperation.24 hours online service affiliates you to contact us.

#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #